SXM4200/SXM6200 network and management cabling

ThinkAgile SXM solutions come cabled for the management and data networks. This information is provided for your reference.

The following image shows the network and management cabling connections for the ThinkAgile SXM SXM4200 and SXM6200 models:

Figure 1. SXM4200/SXM6200 network and management cabling diagram
Graphic showing ThinkAgile SXM SXM4200/SXM6200 network cabling.

Connection notes

Note the following details about the connections.

SXM4200/SXM6200 network cabling tables

The following tables list the point-to-point connections for each ThinkAgile SXM switch.
Table 1. SXM4200/SXM6200 network cabling for RackSwitch G8272 TOR Switch 2
Source PortDestinationConnection type
DevicePortOptic
54Reservedn/an/an/a
53Reservedn/an/an/a
52Reservedn/an/an/a
51Reservedn/an/an/a
50RackSwitch G8272 Switch 1 (TOR-1)50n/aQSFP/QSFP, TwinAx, 1m
49RackSwitch G8272 Switch 1 (TOR-1)49n/aQSFP/QSFP, TwinAx, 1m
48Border-2Customer10G-SRLC/LC Fibre (Customer)
47Border-1Customer10G-SRLC/LC Fibre (Customer)
46RackSwitch G8052 Switch (BMC)52n/aSFP+/SFP+, TwinAx, 1m
45RackSwitch G8272 Switch 1 (TOR-1)45n/aSFP+/SFP+, TwinAx, 1m
44RackSwitch G8272 Switch 1 (TOR-1)44n/aSFP+/SFP+, TwinAx, 1m
43n/an/an/an/a
42n/an/an/an/a
41n/an/an/an/a
40n/an/an/an/a
39n/an/an/an/a
38n/an/an/an/a
37n/an/an/an/a
36n/an/an/an/a
35n/an/an/an/a
34n/an/an/an/a
33n/an/an/an/a
32n/an/an/an/a
31n/an/an/an/a
30n/an/an/an/a
29n/an/an/an/a
28n/an/an/an/a
27n/an/an/an/a
26n/an/an/an/a
25n/an/an/an/a
24n/an/an/an/a
23n/an/an/an/a
22n/an/an/an/a
21n/an/an/an/a
20n/an/an/an/a
19n/an/an/an/a
18n/an/an/an/a
17n/an/an/an/a
16n/an/an/an/a
15n/an/an/an/a
14n/an/an/an/a
13n/an/an/an/a
12System x3650 M5 Server, Node 12Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
11System x3650 M5 Server, Node 11Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
10System x3650 M5 Server, Node 10Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
9System x3650 M5 Server, Node 9Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
8System x3650 M5 Server, Node 8Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
7System x3650 M5 Server, Node 7Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
6System x3650 M5 Server, Node 6Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
5System x3650 M5 Server, Node 5Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
4System x3650 M5 Server, Node 4Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
3System x3650 M5 Server, Node 3Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
2System x3650 M5 Server, Node 2Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
1System x3650 M5 Server, Node 1Mellanox-P2n/aSFP+/SFP+, TwinAx, 1m
Consolen/an/an/an/a
MGMTRackSwitch G8052 Switch (BMC)48n/aCat5e, 1.5m
Table 2. SXM4200/SXM6200 network cabling for RackSwitch G8272 TOR Switch 1
Source PortDestinationConnection type
DevicePortOptic
54Reservedn/an/an/a
53Reservedn/an/an/a
52Reservedn/an/an/a
51Reservedn/an/an/a
50RackSwitch G8272 Switch 2 (TOR-2)50n/aQSFP/QSFP, TwinAx, 1m
49RackSwitch G8272 Switch 2 (TOR-2)49n/aQSFP/QSFP, TwinAx, 1m
48Border-2Customer10G-SRLC/LC Fibre (Customer)
47Border-1Customer10G-SRLC/LC Fibre (Customer)
46RackSwitch G8052 Switch (BMC)51n/aSFP+/SFP+, TwinAx, 1m
45RackSwitch G8272 Switch 2 (TOR-2)45n/aSFP+/SFP+, TwinAx, 1m
44RackSwitch G8272 Switch 2 (TOR-2)44n/aSFP+/SFP+, TwinAx, 1m
43n/an/an/an/a
42n/an/an/an/a
41n/an/an/an/a
40n/an/an/an/a
39n/an/an/an/a
38n/an/an/an/a
37n/an/an/an/a
36n/an/an/an/a
35n/an/an/an/a
34n/an/an/an/a
33n/an/an/an/a
32n/an/an/an/a
31n/an/an/an/a
30n/an/an/an/a
29n/an/an/an/a
28n/an/an/an/a
27n/an/an/an/a
26n/an/an/an/a
25n/an/an/an/a
24n/an/an/an/a
23n/an/an/an/a
22n/an/an/an/a
21n/an/an/an/a
20n/an/an/an/a
19n/an/an/an/a
18n/an/an/an/a
17n/an/an/an/a
16n/an/an/an/a
15n/an/an/an/a
14n/an/an/an/a
13n/an/an/an/a
12System x3650 M5 Server, Node 12Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
11System x3650 M5 Server, Node 11Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
10System x3650 M5 Server, Node 10Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
9System x3650 M5 Server, Node 9Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
8System x3650 M5 Server, Node 8Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
7System x3650 M5 Server, Node 7Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
6System x3650 M5 Server, Node 6Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
5System x3650 M5 Server, Node 5Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
4System x3650 M5 Server, Node 4Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
3System x3650 M5 Server, Node 3Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
2System x3650 M5 Server, Node 2Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
1System x3650 M5 Server, Node 1Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
Consolen/an/an/an/a
MGMTRackSwitch G8052 Switch (BMC)47n/aCat5e, 1.5m
Table 3. SXM4200/SXM6200 network cabling for RackSwitch G8052 BMC Switch
Source PortDestinationConnection type
DevicePortOptic
52RackSwitch G8272 Switch 2 (TOR-2)46n/aSFP+/SFP+, TwinAx, 1m
51RackSwitch G8272 Switch 1 (TOR-1)46n/aSFP+/SFP+, TwinAx, 1m
50n/an/an/an/a
49System x3550 M5 Server (HLH)Mellanox-P1n/aSFP+/SFP+, TwinAx, 1m
48RackSwitch G8272 Switch 2 (TOR-2)MGMT10G-SRCat5e, 1.5m
47RackSwitch G8272 Switch 1 (TOR-1)MGMT10G-SRCat5e, 1.5m
46System x3550 M5 Server (HLH)BMCn/aCat5e, 1.5m
45n/an/an/an/a
44n/an/an/an/a
43n/an/an/an/a
42n/an/an/an/a
41n/an/an/an/a
40n/an/an/an/a
39n/an/an/an/a
38n/an/an/an/a
37n/an/an/an/a
36n/an/an/an/a
35n/an/an/an/a
34n/an/an/an/a
33n/an/an/an/a
32n/an/an/an/a
31n/an/an/an/a
30n/an/an/an/a
29n/an/an/an/a
28n/an/an/an/a
27n/an/an/an/a
26n/an/an/an/a
25n/an/an/an/a
24n/an/an/an/a
23n/an/an/an/a
22n/an/an/an/a
21n/an/an/an/a
20n/an/an/an/a
19n/an/an/an/a
18n/an/an/an/a
17n/an/an/an/a
16n/an/an/an/a
15n/an/an/an/a
14n/an/an/an/a
13n/an/an/an/a
12System x3650 M5 Server, Node 12BMCn/aCat5e, 3m
11System x3650 M5 Server, Node 11BMCn/aCat5e, 3m
10System x3650 M5 Server, Node 10BMCn/aCat5e, 3m
9System x3650 M5 Server, Node 9BMCn/aCat5e, 3m
8System x3650 M5 Server, Node 8BMCn/aCat5e, 3m
7System x3650 M5 Server, Node 7BMCn/aCat5e, 3m
6System x3650 M5 Server, Node 6BMCn/aCat5e, 3m
5System x3650 M5 Server, Node 5BMCn/aCat5e, 3m
4System x3650 M5 Server, Node 4BMCn/aCat5e, 3m
3System x3650 M5 Server, Node 3BMCn/aCat5e, 3m
2System x3650 M5 Server, Node 2BMCn/aCat5e, 3m
1System x3650 M5 Server, Node 1BMCn/aCat5e, 3m
Consolen/an/an/an/a
MGMTn/an/an/an/a